Home

ICS Header 2

CSR1 Current Sensing Relay

The CSR1 current sensing relay is designed to operate in fuel pumps with sealed switch motors, which do not contain an extra switch contact for use with a console or card system.

 

CSR1

 

 

The CSR1 is designed to be wired in series with the pump motor. (black wires)  When the pump motor activates and draws more than 0.5 amps, the CSR1 switches the red wires together, providing a motor return signal for a console or card system. The CSR1 can be located either in the pump, or in the console or card system cabinet.


 

CSR1 wiring

SPECIFICATIONS

INPUT (Black Wires) Output (Red Wires)
Operating Voltage 110 VAC or 220 VAC Switching Voltage 5 to 300 Volts AC or DC
Minimum Trigger Current 0.5 Amps Maximum Current 300 mA
Maximum Current 20 Amps ON Resistance 25-35 Ohms
Switching Time 1 mS    
Case Size 3” x 1.5” x 1”

 

MODEL NUMBERS

MODEL NUMBER
DESCRIPTION
CSR1
Current Sensing Relay

 

ADDITIONAL DOCUMENTATION:

(These files are in PDF Format.)

getacro

 

CSR1 Information Page
CSR1 Installation Instructions